Solar Calculator Canada

Solar Power Calculator for Harbour Grace, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Harbour Grace
  • GPS Coordinates: 47.6796861, -53.2535888
  • Elevation: 51 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Harbour Grace: 36o
  • Average yearly irradiance: 1225.26 kWh/m2
  • Average yearly power output: 105344 kWh
Sun Path Harbour Grace

Average yearly irradiance delivered by the Sun in Harbour Grace is 1225.26/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 105344 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.33 41.33
February 1.88 52.52
March 2.86 88.74
April 4.27 128.25
May 4.78 148.17
June 4.94 148.22
July 5.2 161.34
August 4.59 142.29
September 4.09 122.68
October 2.81 87.23
November 2.01 60.36
December 1.42 44.15
Total yearly 1225.26

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.35 3699.97
February 168.91 4729.57
March 257.34 7977.64
April 377.75 11332.6
May 413.34 12813.7
June 417.7 12531.1
July 431.63 13380.7
August 379.4 11761.5
September 344.47 10334.2
October 242.69 7523.26
November 177.49 5324.6
December 126.95 3935.39
Total yearly 105344

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Harbour Grace solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 91.32 2830.86
February 142.96 4002.77
March 236.43 7329.4
April 369.43 11082.9
May 427.84 13263.1
June 442.56 13276.9
July 451.21 13987.5
August 379.03 11750
September 317.71 9531.23
October 205.49 6370.32
November 134.65 4039.38
December 91.08 2823.51
Total yearly 100288

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 99.28 3077.72
February 150.73 4220.33
March 243.59 7551.35
April 374.65 11239.4
May 427.2 13243.1
June 439.38 13181.3
July 449.58 13936.9
August 382.2 11848.1
September 327.19 9815.83
October 216.66 6716.61
November 146.76 4402.91
December 101.1 3134
Total yearly 102368

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.5 3301.37
February 157.54 4411.19
March 249.41 7731.63
April 377.86 11335.8
May 424.78 13168.1
June 434.31 13029.4
July 446.08 13828.4
August 383.4 11885.3
September 334.76 10042.7
October 226.43 7019.29
November 157.75 4732.37
December 110.26 3418.21
Total yearly 103904

Harbour Grace Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.93 3500.83
February 163.37 4574.5
March 253.85 7869.33
April 379.02 11370.5
May 420.91 13048.3
June 427.88 12836.4
July 440.57 13657.6
August 382.67 11862.8
September 340.36 10210.7
October 234.74 7277.08
November 167.55 5026.44
December 118.54 3674.85
Total yearly 104909

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.07% angle of incidence loss and -1.44% temperature and irradiance loss. This totals to about -14.02%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LaScieMacGregorMing's BightMilestoneRiversParson's PondVauxhallRedcliffKiplingFrancisRapid CityFleur de LysStonewallStavelyHamiotaRouleauGladstoneDaniel's HarbourLac du BonnetWapellaWhitewoodNantonBroadviewRocanvilleTeulonMurdochville